KNAUF Therm PRO Facade / Roof / Floor EPS 80 λ 37
KNAUF Therm PRO Facade / Roof / Floor EPS 80 λ 37
MARKING BY STANDARD
KNAUF Therm PRO Facade / Roof / Floor EPS 80 λ 37 Styrofoam panels are marked with the following code in accordance with EN 13163: 2012 + A1: 2015 EPS –EN 13163-T (1) -L (2) -W (2) -S (2) -P (5) -BS125-CS (10) 80-DS (N) 2-DS (70, -) 1-TR100
λD Thermal conductivity W/(mK) | ≤ 0,037 |
Shape | Rectangular or milled |
Dimensions | 1000 x 500mm max wym.: 4000 x 1200mm |
Compressive stress level at 10% relative deformation (kPa) | CS(10)80 (≥ 80) |
Fire resistance | Self-extinguishing |
Fire resistance class | E |
Flexural strength level (kPa) | BS125 ( ≥ 125) |
Tensile strength perpendicular to surface (kPa) | TR100 ( ≥ 100) |